IAC
America offers the broadest range of silencers/louvers
in the industry. All of IACs silencers were developed
in response to specific requirements from acoustical
consultants, consulting engineers, owners, and contractors.
Having been pre-tested for performance, they provide
the most economical choices for solving the wide variety
of noise control problems encountered in HVAC engineering.
-
Quiet-Duct Ultra/Low For conventional
applications where guaranteed performance is required
down to 31.5 Hz, including finer resolution of one-third-octave-band
data for applications requiring full octave band
performance to match specific sound sources.
-
Quiet-Duct Ultra/Green A 100% environmentally
friendly attenuation solution. Silence is achieved
through the use of recycled acoustic fill material.
Ideal for any clean and green application.
-
Quiet-Duct Ultra/ZAPD For applications
in which acoustic attenuation is required and no
allowance can be made for pressure loss. A Zero-Added-Pressure-Drop
silencer is ideal of high velocity systems or systems
that have little or no room for additional pressure
drop.
-
Quiet-Duct Commercial Series For conventional
applications including low frequency. Silencers
are specifically engineered to enhance insertion
loss in the 63 Hz, 125 Hz, and 250 Hz octave bands.
-
Clean-Flow Rectangular Silencers For systems
requiring a higher degree of cleanliness and hygiene
such as in hospitals or clean rooms. Linings on
the fill material guard against erosion of particulate
matter into the air-stream. Specific internal construction
features protect the lining against chafing or premature
failure and are necessary to maintain the rated
aero-acoustic performance.
-
Conic-Flow Tubular Silencers For silencer
applications including low frequency. Silencers
are specifically engineered to enhance insertion
loss in the 63 Hz, 125 Hz, and 250 Hz octave bands.
-
D-Duct Acoustic Diffuser Silencers
For use on axial-fan systems. The combined interior
diffuser cone and exterior square jacket casing
make these units aerodynamic-regain devices as well
as silencers.
-
Ultra-Pals Rectangular Packless Silencers
The ultimate solution for ultra-clean environments
and corrosive/flammable environments. The complete
absence of fill makes Ultra-Pals Rectangular
-
Packless Silencers ideally suited for any application
where particulate matter or fiber erosion from conventional
fill materials could contaminate the air/gas streams.
The complete absence of fill combined with ease
of cleaning and draining, makes Ultra-Pals
Silencers ideal in corrosive/flammable environments
and for facilities handling gasoline, grease, solvents,
and other hazardous materials.
Ultra-Pals Tubular Packless
Silencers For small-diameter circular
duct systems such as fume hoods. Additionally, the packless
design of these units makes them equally applicable
to the types of systems mentioned for the Rectangular
Ultra-Pals Silencers.
Acoustic Louvers
Twelve inch deep model R and model LP
louvers allow for ventilation while reducing noise transmission
from building machine rooms. Four inch and six inch
Slimshield models are compact for use in walls,
doors, or equipment enclosures where airflow is required.
IAC has more than five decades of experience in the
design and manufacture of silencers for jet engines,
gas turbines, forced draft fans and air handling systems.
The result is an extensive range of standard silencer
configurations incorporating innovative design and manufacturing
features with performance certified in IACs Aero-Acoustic
NVLAP-Certified Laboratory.
Performance ratings for both Dynamic Insertion Loss
and Aerodynamic Pressure Drop for all Power-Flow Silencer
designs have been certified in accordance with ASTM
E477 and applicable sections of ISO 7235:1991 and British
Standard 4718-1971 in our full-scale wind tunnel and
corroborated by independent laboratories.
Some typical applications for Power-Flow Silencers
include:
- Gas Turbines
- Compressors
- Diesel Engines
- Cooling Towers
- Mechanical Draft Fans
- Air Cooled Condensers
- Scrubbers
- Power Plants
- Wind Tunnels
- Dust collectors
- Furnace Exhaust
- Engine Test Cells
- Incinerators
- Refineries
- Steel Mills
- Test Facilities
- Tunnel Ventilation
- Jet Fans
- Chemical Process Plants
-
any Air/Gas Handling Installation
- IAC Power-Flow Stack Insert Silencers
are available in 28 standard aero-acoustic designs
to solve most stack noise problems. Special designs
are developed in the IAC Aero-Acoustic Laboratory
as may be required.
- Cost-Effective Silencing for Induced
Draft Fan Systems:
- Scrubbers
- Paint Spray Facilities
- Precipitators
- Cupolas
- Heat Recovery Boil Stacks
- Coke Oven Emission Control Systems
- Industrial Ventilation Systems
- IAC Power-Flow ACoustic FIlter
(ACFI) Tuned Dissipative Silencers
IAC ACFI Silencers are designed to provide noise control
for induced draft fans in power plants, ventilation
system in steel mills, coal mines, aluminum reduction
facilities, and other processes that involve gas streams
which often contain appreciable amounts of moist particulate
which can quickly clog and render conventional parallel
baffle absorptive silencers ineffective.
Take advantage of IACs know-how
the most
extensive in the noise control industry. Special silencer
configurations are available to satisfy the most stringent
criteria.
Click
here to visit IAC's website.
|